<?xml version='1.0' encoding='UTF-8'?>
<cpq_bundle version="2.0.1.0">
  <divisions>
    <division key="6">
      <division_xlate lang="en">Server</division_xlate>
      <division_xlate lang="ja">サーバ</division_xlate>
    </division>
  </divisions>
  <operating_systems>
    <operating_system key="9398">
      <operating_system_xlate>SUSE Linux Enterprise Server 15</operating_system_xlate>
    </operating_system>
  </operating_systems>
  <products>
    <product rom="P89"/>
    <product rom="U44"/>
    <product rom="A41"/>
    <product rom="I37"/>
    <product rom="I36"/>
    <product rom="U37"/>
    <product rom="U43"/>
    <product rom="U40"/>
    <product rom="U34"/>
    <product rom="U20"/>
    <product rom="U32"/>
    <product rom="A40"/>
    <product rom="U30"/>
    <product rom="U41"/>
    <product rom="U33"/>
    <product rom="U45"/>
    <product rom="U38"/>
    <product rom="I42"/>
    <product rom="I43"/>
    <product rom="U39"/>
    <product rom="I41"/>
  </products>
  <category key="11400032">
    <category_xlate lang="en">Application - System Management</category_xlate>
    <category_xlate lang="ja">アプリケーション - システム マネジメント</category_xlate>
  </category>
  <id product="ba55a5bc9a0b4d9f80f9c7282e3a790d" version="f67502ab0f334ea19a159b9f421f79f6"/>
  <name>
    <name_xlate lang="en">SLES15 SP3 supplement for SPP</name_xlate>
    <name_xlate lang="ja">SLES15 SP3 supplement for SPP</name_xlate>
  </name>
  <version value="2021.05.0" revision="" type_of_change="0"/>
  <languages langlist="en,ja">
    <languages_xlate lang="en">English (US),Japanese</languages_xlate>
    <languages_xlate lang="ja">日本語,英語（US）</languages_xlate>
  </languages>
  <release_date year="2021" month="08" day="05" hour="21" minute="26" second="19"/>
  <description>
    <description_xlate lang="en"><![CDATA[This supplement contains updated drivers to support SUSE Enterprise Linux 15 SP3 with the Service Pack for ProLiant.  Before beginning installation, the supplement should be copied directly to a separate folder on a test platform.]]></description_xlate>
    <description_xlate lang="ja"><![CDATA[This supplement contains updated drivers to support SUSE Enterprise Linux 15 SP3 with the Service Pack for ProLiant.  Before beginning installation, the supplement should be copied directly to a separate folder on a test platform.]]></description_xlate>
  </description>
  <prerequisite_notes>
    <prerequisite_notes_xlate lang="en">
      <prerequisite_notes_xlate_part><![CDATA[<p style="color: rgb(0, 0, 0); font-family: Verdana, Helvetica, sans-serif; font-size: 10.9px;">
 <b>IMPORTANT:</b>&nbsp;Before deploying software updates on a target system, be sure that a recent backup of the target system is available in the event the deployment procedure fails.</p>
<p style="color: rgb(0, 0, 0); font-family: Verdana, Helvetica, sans-serif; font-size: 10.9px;">
 To successfully deploy HP SUM on remote target systems based on a Linux operating system, the following must be available: &nbsp;</p>
<ul style="color: rgb(0, 0, 0); font-family: Verdana, Helvetica, sans-serif; font-size: 10.9px; list-style-type: square;">
 <li style="margin-left: 10px;">
  libcrypt.so</li>
 <li style="margin-left: 10px;">
  libcrypt.so.1</li>
 <li style="margin-left: 10px;">
  /usr/lib/libqlsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib64/libqlsdm-x86_64.so</li>
 <li style="margin-left: 10px;">
  /lib/cim/libqlsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib/libemsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib64/libemsdm.so</li>
 <li style="margin-left: 10px;">
  /lib/cim/libemsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib/bfahbaapi.so</li>
 <li style="margin-left: 10px;">
  /usr/lib64/bfahbaapi.so</li>
 <li style="margin-left: 10px;">
  /lib/cim/bfahbaapi.so</li>
 <li style="margin-left: 10px;">
  linux-vdso.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libcrypt.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libpthread.so.0</li>
 <li style="margin-left: 10px;">
  /lib64/libz.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libdl.so.2</li>
 <li style="margin-left: 10px;">
  /lib64/librt.so.1</li>
 <li style="margin-left: 10px;">
  /usr/lib64/libstdc++.so.6</li>
 <li style="margin-left: 10px;">
  /lib64/libm.so.6</li>
 <li style="margin-left: 10px;">
  /lib64/libgcc_s.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libc.so.6</li>
 <li style="margin-left: 10px;">
  /lib64/ld-linux-x86-64.so.2</li>
</ul>
]]></prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
    <prerequisite_notes_xlate lang="ja">
      <prerequisite_notes_xlate_part><![CDATA[<p style="color: rgb(0, 0, 0); font-family: Verdana, Helvetica, sans-serif; font-size: 10.9px;">
 <b>IMPORTANT:</b>&nbsp;Before deploying software updates on a target system, be sure that a recent backup of the target system is available in the event the deployment procedure fails.</p>
<p style="color: rgb(0, 0, 0); font-family: Verdana, Helvetica, sans-serif; font-size: 10.9px;">
 To successfully deploy HP SUM on remote target systems based on a Linux operating system, the following must be available: &nbsp;</p>
<ul style="color: rgb(0, 0, 0); font-family: Verdana, Helvetica, sans-serif; font-size: 10.9px; list-style-type: square;">
 <li style="margin-left: 10px;">
  libcrypt.so</li>
 <li style="margin-left: 10px;">
  libcrypt.so.1</li>
 <li style="margin-left: 10px;">
  /usr/lib/libqlsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib64/libqlsdm-x86_64.so</li>
 <li style="margin-left: 10px;">
  /lib/cim/libqlsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib/libemsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib64/libemsdm.so</li>
 <li style="margin-left: 10px;">
  /lib/cim/libemsdm.so</li>
 <li style="margin-left: 10px;">
  /usr/lib/bfahbaapi.so</li>
 <li style="margin-left: 10px;">
  /usr/lib64/bfahbaapi.so</li>
 <li style="margin-left: 10px;">
  /lib/cim/bfahbaapi.so</li>
 <li style="margin-left: 10px;">
  linux-vdso.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libcrypt.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libpthread.so.0</li>
 <li style="margin-left: 10px;">
  /lib64/libz.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libdl.so.2</li>
 <li style="margin-left: 10px;">
  /lib64/librt.so.1</li>
 <li style="margin-left: 10px;">
  /usr/lib64/libstdc++.so.6</li>
 <li style="margin-left: 10px;">
  /lib64/libm.so.6</li>
 <li style="margin-left: 10px;">
  /lib64/libgcc_s.so.1</li>
 <li style="margin-left: 10px;">
  /lib64/libc.so.6</li>
 <li style="margin-left: 10px;">
  /lib64/ld-linux-x86-64.so.2</li>
</ul>
]]></prerequisite_notes_xlate_part>
    </prerequisite_notes_xlate>
  </prerequisite_notes>
  <installation_notes>
    <installation_notes_xlate lang="en">
      <installation_notes_xlate_part><![CDATA[<p><strong>Installation of the Supplement for Service Pack for ProLiant Using Autorun: supplements may be installed via autorun if autorun is configured on the target Linux server</strong>.</p>

<p>Several autorun utilities are available for download from various Internet sites. These distributions will typically mount the CD-ROM on /media/cdrom.</p>

<p>For the purposes of these instructions, the CD-ROM is assumed to have been mounted on /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions.</p>

<p><strong>Manual Installation of the Supplement for Service Pack for ProLiant&nbsp;:</strong></p>

<ul style="list-style-type:square">
	<li>For the remainder of this discussion, the CD mount directory will be considered to be /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions. If the CD-ROM mount point is not defined in /etc/fstab, a complete mount command will be required.</li>
	<li>Download the latest supplemental as applicable. It will be in zipped format.</li>
	<li>Login on the console as root</li>
	<li>Copy the supplement on your local server. The supplement will be in zipped format.</li>
	<li>Unzip/ Untar the supplement.</li>
	<li>Go to the supplement folder either through GUI and run Smart Update Manager&nbsp;file or in command prompt give ./hpsum. Make sure to give read write permission to this file.</li>
</ul>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Or</p>

<ul style="list-style-type:square">
	<li>If the Operating is of x64bit architecture, go to x64bit folder in supplement, and run ./hpsum_bin_x64. This will launch &nbsp;Smart Update Manager&nbsp;in the browser automatically.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>
	<li>If the Operating system is of x86bit architecture, go to x86 folder in supplement, and run ./hpsum_bin_x86. This will launch &nbsp;Smart Update Manager in the browser automatically.</li>
	<li><u>Note</u>: Make sure to have the supported browser installed on your system.&nbsp;</li>
</ul>

<p>The installer will open an interactive session which will allow you to install the Linux&nbsp;Service Pack for ProLiant supplement.</p>

<p><strong>NOTE</strong>: Be sure to include the version of the compatibility libraries that is appropriate for your architecture. In some cases, there are separate 32-bit and 64-bit compatibility libraries for a given distribution.</p>

<p>For a current list of supported Linux distributions and versions (and their associated errata kernels), see the&nbsp;<a href="https://www.hpe.com/us/en/servers/server-operating-systems.html" style="color: blue; text-decoration: none;">operating system support matrixes&nbsp;</a>. The supplements are designed for use after you install the operating system so that you can update drivers, install&nbsp; utilities (such as Health and iLO drivers), and install agents (Server, NIC, and Storage).</p>
]]></installation_notes_xlate_part>
    </installation_notes_xlate>
    <installation_notes_xlate lang="ja">
      <installation_notes_xlate_part><![CDATA[<p><strong>Installation of the Supplement for Service Pack for ProLiant Using Autorun: supplements may be installed via autorun if autorun is configured on the target Linux server</strong>.</p>

<p>Several autorun utilities are available for download from various Internet sites. These distributions will typically mount the CD-ROM on /media/cdrom.</p>

<p>For the purposes of these instructions, the CD-ROM is assumed to have been mounted on /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions.</p>

<p><strong>Manual Installation of the Supplement for Service Pack for ProLiant&nbsp;:</strong></p>

<ul style="list-style-type:square">
	<li>For the remainder of this discussion, the CD mount directory will be considered to be /mnt/mnt. The actual mount point should replace /mnt/mnt when executing these instructions. If the CD-ROM mount point is not defined in /etc/fstab, a complete mount command will be required.</li>
	<li>Download the latest supplemental as applicable. It will be in zipped format.</li>
	<li>Login on the console as root</li>
	<li>Copy the supplement on your local server. The supplement will be in zipped format.</li>
	<li>Unzip/ Untar the supplement.</li>
	<li>Go to the supplement folder either through GUI and run Smart Update Manager&nbsp;file or in command prompt give ./hpsum. Make sure to give read write permission to this file.</li>
</ul>

<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Or</p>

<ul style="list-style-type:square">
	<li>If the Operating is of x64bit architecture, go to x64bit folder in supplement, and run ./hpsum_bin_x64. This will launch &nbsp;Smart Update Manager&nbsp;in the browser automatically.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>
	<li>If the Operating system is of x86bit architecture, go to x86 folder in supplement, and run ./hpsum_bin_x86. This will launch &nbsp;Smart Update Manager in the browser automatically.</li>
	<li><u>Note</u>: Make sure to have the supported browser installed on your system.&nbsp;</li>
</ul>

<p>The installer will open an interactive session which will allow you to install the Linux&nbsp;Service Pack for ProLiant supplement.</p>

<p><strong>NOTE</strong>: Be sure to include the version of the compatibility libraries that is appropriate for your architecture. In some cases, there are separate 32-bit and 64-bit compatibility libraries for a given distribution.</p>

<p>For a current list of supported Linux distributions and versions (and their associated errata kernels), see the&nbsp;<a href="https://www.hpe.com/us/en/servers/server-operating-systems.html" style="color: blue; text-decoration: none;">operating system support matrixes&nbsp;</a>. The supplements are designed for use after you install the operating system so that you can update drivers, install&nbsp; utilities (such as Health and iLO drivers), and install agents (Server, NIC, and Storage).</p>
]]></installation_notes_xlate_part>
    </installation_notes_xlate>
  </installation_notes>
  <availability_notes>
    <availability_notes_xlate lang="en">
      <availability_notes_xlate_part><![CDATA[]]></availability_notes_xlate_part>
    </availability_notes_xlate>
    <availability_notes_xlate lang="ja">
      <availability_notes_xlate_part><![CDATA[]]></availability_notes_xlate_part>
    </availability_notes_xlate>
  </availability_notes>
  <documentation_notes>
    <documentation_notes_xlate lang="en">
      <documentation_notes_xlate_part><![CDATA[]]></documentation_notes_xlate_part>
    </documentation_notes_xlate>
    <documentation_notes_xlate lang="ja">
      <documentation_notes_xlate_part><![CDATA[]]></documentation_notes_xlate_part>
    </documentation_notes_xlate>
  </documentation_notes>
  <revision_history>
    <revision>
      <version value="2021.05.0" revision="" type_of_change="0"/>
      <revision_enhancements_xlate lang="en">
        <revision_enhancements_xlate_part><![CDATA[<p>The release notes for this version of the supplement are available at:&nbsp;<a href="https://www.hpe.com/servers/spp/download">https://www.hpe.com/servers/spp/download</a>&nbsp;&nbsp;&nbsp;Click on the documentation tab.</p>

<p>&nbsp;</p>
]]></revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="ja">
        <revision_enhancements_xlate_part><![CDATA[<p>The release notes for this version of the supplement are available at:&nbsp;<a href="https://www.hpe.com/servers/spp/download">https://www.hpe.com/servers/spp/download</a>&nbsp;&nbsp;&nbsp;Click on the documentation tab.</p>

<p>&nbsp;</p>
]]></revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="en">
        <revision_enhancements_xlate_part/>
      </revision_enhancements_xlate>
      <revision_fixes_xlate lang="en">
        <revision_fixes_xlate_part/>
      </revision_fixes_xlate>
      <revision_fixes_xlate lang="ja">
        <revision_fixes_xlate_part/>
      </revision_fixes_xlate>
      <revision_fixes_xlate lang="en">
        <revision_fixes_xlate_part/>
      </revision_fixes_xlate>
    </revision>
    <revision>
      <version/>
      <revision_enhancements_xlate lang="ja">
        <revision_enhancements_xlate_part><![CDATA[<p>The release notes for this version of the supplement are available at:&nbsp;<a href="http://www.hpe.com/servers/spp/download#tab=TAB4">http://www.hpe.com/servers/spp/download#tab=TAB4</a>.&nbsp;&nbsp;&nbsp;</p>

<p>&nbsp;</p>
]]></revision_enhancements_xlate_part>
      </revision_enhancements_xlate>
      <revision_enhancements_xlate lang="en">
        <revision_enhancements_xlate_part/>
      </revision_enhancements_xlate>
      <revision_fixes_xlate lang="ja">
        <revision_fixes_xlate_part/>
      </revision_fixes_xlate>
      <revision_fixes_xlate lang="en">
        <revision_fixes_xlate_part/>
      </revision_fixes_xlate>
    </revision>
  </revision_history>
  <prerequisites>
    <supported_operating_systems>
      <supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="15" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 15"/>
    </supported_operating_systems>
  </prerequisites>
  <contents>
    <package install="yes">hponcfg-5.6.0-0.x86_64.rpm</package>
    <package install="yes">hp-health-10.92-6.6.sles15.x86_64.rpm</package>
    <package install="yes">amsd-2.4.1-1571.4.sles15.x86_64.rpm</package>
    <package install="yes">hp-snmp-agents-10.93-680.4.sles15.x86_64.rpm</package>
    <package install="yes">sut-2.8.0-26.linux.x86_64.rpm</package>
    <package install="yes">smartpqi-kmp-default-2.1.12-025.sles15sp2.x86_64.rpm</package>
    <package install="yes">smartpqi-kmp-default-2.1.12-025.sles15sp3.x86_64.rpm</package>
    <package install="yes">hpsa-kmp-default-3.4.20-210.sles15sp3.x86_64.rpm</package>
    <package install="yes">hpsa-kmp-default-3.4.20-210.sles15sp2.x86_64.rpm</package>
    <package install="yes">hpdsa-kmp-default-1.2.10-196.sles15sp3.x86_64.rpm</package>
    <package install="yes">hpdsa-kmp-default-1.2.10-196.sles15sp2.x86_64.rpm</package>
    <package install="yes">hp-ams-2.10.3-877.3.sles15.x86_64.rpm</package>
    <package install="yes">hp-smh-templates-10.8.1-1487.3.noarch.rpm</package>
  </contents>
</cpq_bundle>
