    "DeviceClass": "79f0c163-0c13-4662-9dea-09235fef90cb", 
    "Devices": {
        "Device": [
            {
                "DeviceName": "Broadcom NetXtreme-E BCM57608 100GbE 2p QSFP112 Adptr", 
                "FirmwareImages": [
                    {
                        "DelayAfterInstallSec": 0, 
                        "DirectFlashOK": true, 
                        "FileName": "BCM235.1.164.14_BCM957608-P2100HQF00.HPb", 
                        "InstallDurationSec": 360, 
                        "Order": 1, 
                        "PLDMImage": true, 
                        "ResetRequired": true, 
                        "ServerPowerOff": false, 
                        "SysPowerOn": true, 
                        "Type": "Firmware", 
                        "UEFIFlashable": false
                    }
                ], 
                "Target": "a6b1a447-382a-5a4f-14e4-176014e4e124", 
                "Version": "235.1.164.14"
            }
        ]
    }, 
    "Package": {
        "Category": [
            {
                "Lang": "en", 
                "Value": "Firmware - Network"
            }
        ], 
        "Description": [
            {
                "Lang": "en", 
                "Value": "This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM57608 100GbE 2p Gigabit Ethernet NIC firmware."
            }
        ], 
        "Divisions": [
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Networking"
                    }
                ]
            }, 
            {
                "Divsion": [
                    {
                        "Lang": "en", 
                        "Value": "Server"
                    }
                ]
            }
        ], 
        "Files": [
            {
                "Bytes": "3410308", 
                "DateModified": "2025-12-12T03:37:19", 
                "FileList": [
                    "BCM235.1.164.14_BCM957608-P2100HQF00.HPb", 
                    "BCM235.1.164.14_BCM957608-P2100HQF00.xml", 
                    "payload.json"
                ], 
                "MD5Sum": "3e92e6863058ff6b3e37f01ac9198906", 
                "Name": "BCM235.1.164.14_BCM957608-P2100HQF00.fwpkg", 
                "Release": "2025-12-12T03:33:27", 
                "Revision": "", 
                "SHA1Sum": "3edeb1b34965e88e26c36c2d8a9f22c7bf75962c", 
                "SHA256Sum": "facd165e8ad6185e0a94ce813bef8d68dd5fdb6ad693e32b81c392f729d27f87", 
                "Size": "3.25MB", 
                "TargetGUIDs": [
                    "a6b1a447-382a-5a4f-14e4-176014e4e124"
                ], 
                "TypeOfChange": "1", 
                "Version": "235.1.164.14"
            }
        ], 
        "Id": {
            "Product": "ffe236b3c9414886ad6bebd19a87b8d3", 
            "Version": "2902f5e1f8554204b995d5eb26637bee"
        }, 
        "Installation": {
            "Command": "", 
            "CommandParams": "", 
            "InstallCaps": {
                "NeedUserAction": "no", 
                "Silent": "no"
            }, 
            "PerDeviceInstallTimeSeconds": 360, 
            "RebootDetails": [
                {
                    "Lang": "en", 
                    "Value": "Reboot is required after installation for updates to take effect and hardware stability to be maintained."
                }
            ], 
            "RebootRequired": "yes", 
            "RebootRequirement": "Required"
        }, 
        "InstallationDependency": {}, 
        "InstallationNotes": [
            {
                "Lang": "en", 
                "Value": "<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"
            }
        ], 
        "ManufacturerName": [
            {
                "Lang": "en", 
                "Value": "Hewlett Packard Enterprise"
            }
        ], 
        "Name": [
            {
                "Lang": "en", 
                "Value": "Broadcom Firmware Package for BCM57608 100GbE 2p Adapter"
            }
        ], 
        "Prerequisites": {
            "RequiredDiskSpace": {
                "SizeKB": "11000"
            }, 
            "SupportedDevices": [
                {
                    "Dev": "1760", 
                    "SubDev": "E124", 
                    "SubVen": "14E4", 
                    "TargetGUID": "a6b1a447-382a-5a4f-14e4-176014e4e124", 
                    "Type": "pci", 
                    "Ven": "14E4"
                }, 
                {
                    "Dev": "1760", 
                    "SubDev": "E124", 
                    "SubVen": "14E4", 
                    "TargetGUID": "a6b1a447-382a-5a4f-14e4-176014e4e124", 
                    "Type": "pci", 
                    "Ven": "14E4"
                }, 
                {
                    "Dev": "1760", 
                    "SubDev": "E124", 
                    "SubVen": "14E4", 
                    "TargetGUID": "a6b1a447-382a-5a4f-14e4-176014e4e124", 
                    "Type": "pci", 
                    "Ven": "14E4"
                }
            ], 
            "SupportedOperatingSystems": [
                {
                    "Major": "10", 
                    "Maximumbuild": "18999", 
                    "Minimumbuild": "17600", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2019", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Maximumbuild": "25398", 
                    "Minimumbuild": "20317", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2022", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Minimumbuild": "25399", 
                    "Minor": "0", 
                    "Name": "Microsoft Windows Server 2025", 
                    "Platform": "nt_x86-64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "0", 
                    "Minor": "0", 
                    "Name": "Cross Operating System", 
                    "Platform": "oi", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "10", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 10", 
                    "Platform": "Red_Hat_Enterprise_Linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "8", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 8 Server", 
                    "Platform": "red_hat_enterprise_linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "Red Hat Enterprise Linux 9 Server", 
                    "Platform": "red_hat_enterprise_linux_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "15", 
                    "Minor": "0", 
                    "Name": "SUSE Linux Enterprise Server 15", 
                    "Platform": "suse_linux_enterprise_server_x86_64", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "8", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 8.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }, 
                {
                    "Major": "9", 
                    "Minor": "0", 
                    "Name": "VMware ESXi 9.0", 
                    "Platform": "vmware_esx_server", 
                    "Sr": "OEM"
                }
            ], 
            "SupportedPlatforms": false
        }, 
        "ReleaseDate": "2026-01-12T03:13:36", 
        "RevisionHistory": [
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p>This product enhances the handling of link status during D0 to D3 power domain transition.<br />\n&nbsp;</p>\n", 
                        "Fixes": "<ul>\n\t<li>This product fixes the issue where, in breakout mode, a cable remove or insert failed to bring the link up because the module did not exit the DPDeactivated (Data Path Deactivated) state in time.</li>\n\t<li>This product fixes the issue where RDE NetworkAdapter schema Location property is missing</li>\n\t<li>This product fixes the issue where the adapter might be missing during the system reboot.<br />\n\t&nbsp;</li>\n</ul>\n", 
                        "Lang": "en"
                    }
                ], 
                "Version": "235.1.164.14"
            }, 
            {
                "ReleaseNotes": [
                    {
                        "Enhancements": "<p>This product enhances the handling of link status during D0 to D3 power domain transition.<br />\n&nbsp;</p>\n", 
                        "Fixes": "<ul>\n\t<li>This product fixes the issue where, in breakout mode, a cable remove or insert failed to bring the link up because the module did not exit the DPDeactivated (Data Path Deactivated) state in time.</li>\n\t<li>This product fixes the issue where RDE NetworkAdapter schema Location property is missing</li>\n\t<li>This product fixes the issue where the adapter might be missing during the system reboot.<br />\n\t&nbsp;</li>\n</ul>\n", 
                        "Lang": "en"
                    }
                ], 
                "Version": "235.1.160.0"
            }
        ], 
        "SWKeys": [
            {
                "Name": "BCM_NXE_57608_2P100_PKG", 
                "SWKeyExpectedPath": "firmware:nic"
            }
        ], 
        "SchemaVersion": "2.0.0.0", 
        "SupportedProducts": [
            {
                "Family": "U71", 
                "Model": "HPE ProLiant Compute DL320 Gen12 Server"
            }, 
            {
                "Family": "U54", 
                "Model": "HPE ProLiant DL360 Gen11 Server"
            }, 
            {
                "Family": "U65", 
                "Model": "HPE ProLiant DL20 Gen11"
            }, 
            {
                "Family": "U66", 
                "Model": "HPE ProLiant Compute XD230 (U66)"
            }, 
            {
                "Family": "U70", 
                "Model": "HPE ProLiant Compute DL380a Gen12 (U70)"
            }, 
            {
                "Family": "U68", 
                "Model": "HPE Alletra Storage Server 4210"
            }, 
            {
                "Family": "A55", 
                "Model": "HPE ProLiant DL365 Gen11 Server"
            }, 
            {
                "Family": "U68", 
                "Model": "HPE ProLiant Compute ML350 Gen12"
            }, 
            {
                "Family": "U72", 
                "Model": "HPE ProLiant Compute DL380a Gen12 (U72)"
            }, 
            {
                "Family": "A59", 
                "Model": "HPE ProLiant Compute XD685"
            }, 
            {
                "Family": "U77", 
                "Model": "HPE ProLiant Compute DL110 Gen12"
            }, 
            {
                "Family": "U54", 
                "Model": "HPE ProLiant ML350 Gen11 Server"
            }, 
            {
                "Family": "A66", 
                "Model": "HPE ProLiant Compute DL345 Gen12 Server"
            }, 
            {
                "Family": "A58", 
                "Model": "HPE ProLiant DL145 Gen11"
            }, 
            {
                "Family": "U63", 
                "Model": "HPE ProLiant DL320 Gen11 Server"
            }, 
            {
                "Family": "H11", 
                "Model": "HPE Compute Edge Server e930t"
            }, 
            {
                "Family": "U54", 
                "Model": "HPE ProLiant DL380 Gen11 Server"
            }, 
            {
                "Family": "U68", 
                "Model": "HPE ProLiant Compute DL360 Gen12"
            }, 
            {
                "Family": "U58", 
                "Model": "HPE ProLiant DL380a Gen11"
            }, 
            {
                "Family": "U72", 
                "Model": "HPE ProLiant Compute DL580 Gen12"
            }, 
            {
                "Family": "U63", 
                "Model": "HPE ProLiant ML110 Gen11 Server"
            }, 
            {
                "Family": "U65", 
                "Model": "HPE MicroServer Gen11"
            }, 
            {
                "Family": "U59", 
                "Model": "HPE ProLiant DL560 Gen11 Server"
            }, 
            {
                "Family": "U65", 
                "Model": "HPE ProLiant ML30 Gen11"
            }, 
            {
                "Family": "A55", 
                "Model": "HPE ProLiant DL385 Gen11 Server"
            }, 
            {
                "Family": "A56", 
                "Model": "HPE ProLiant DL325 Gen11 Server"
            }, 
            {
                "Family": "A56", 
                "Model": "HPE ProLiant DL345 Gen11 Server"
            }, 
            {
                "Family": "U69", 
                "Model": "HPE ProLiant Compute DL320 Gen12 SP Server"
            }, 
            {
                "Family": "U71", 
                "Model": "HPE ProLiant Compute DL340 Gen12 Server"
            }, 
            {
                "Family": "U62", 
                "Model": "HPE ProLiant DL110 Gen11 Server"
            }, 
            {
                "Family": "U68", 
                "Model": "HPE ProLiant Compute DL380 Gen12"
            }, 
            {
                "Family": "A66", 
                "Model": "HPE ProLiant Compute DL325 Gen12 Server"
            }, 
            {
                "Family": "U69", 
                "Model": "HPE ProLiant Compute DL340 Gen12 SP Server"
            }
        ], 
        "UpgradeRequirements": "Recommended"
    }, 
    "PackageFormat": "FWPKG-v2", 
    "Type": "Firmware", 
    "UpdatableBy": [
        "Bmc"
    ]
}