rsd_lib.resources.v2_1.chassis.thermal_zone Module¶rsd_lib.resources.v2_1.chassis.thermal_zone.FanCollectionField(*args, **kwargs)¶Bases: sushy.resources.base.ListField
name = <sushy.resources.base.Field object>¶The Power Supply name
rack_location = <rsd_lib.resources.v2_1.common.rack_location.RackLocationField object>¶The Fan physical location
reading_rpm = <sushy.resources.base.Field object>¶Fan RPM reading
status = <rsd_lib.base.StatusField object>¶The Fan status
rsd_lib.resources.v2_1.chassis.thermal_zone.TemperatureSensorCollectionField(*args, **kwargs)¶Bases: sushy.resources.base.ListField
name = <sushy.resources.base.Field object>¶The Power Supply name
physical_context = <sushy.resources.base.Field object>¶Describes the area or device to which this temperature measurement applies: “Intake” - The intake point of the chassis “Exhaust” - The exhaust point of the chassis “Backplane” - A backplane within the chassis “PowerSupply” - A power supply “SystemBoard” - The system board (PCB) “ComputeBay” - Within a compute bay “PowerSupplyBay” - Within a power supply bay
reading_celsius = <sushy.resources.base.Field object>¶Current value of the temperature sensor’s reading
status = <rsd_lib.base.StatusField object>¶The temperature sensors status
rsd_lib.resources.v2_1.chassis.thermal_zone.ThermalZone(connector, path='', redfish_version=None, registries=None, reader=None)¶Bases: rsd_lib.base.ResourceBase
desired_speed_pwm = <sushy.resources.base.Field object>¶The desired FAN speed in current ThermalZone present in PWM unit
desired_speed_rpm = <sushy.resources.base.Field object>¶The desired FAN speed in current ThermalZone present in RPM unit
fans = <rsd_lib.resources.v2_1.chassis.thermal_zone.FanCollectionField object>¶Details of the fans associated with this thermal zone
max_fans_supported = <sushy.resources.base.Field object>¶Number of maximum fans that can be installed in a given Thermal Zone
number_of_fans_present = <sushy.resources.base.Field object>¶The existing number of fans in current ThermalZone
presence = <sushy.resources.base.Field object>¶Indicates the aggregated Power Supply Unit presence information Aggregated Power Supply Unit presence format: Length of string indicate total slot of Power Supply Units in PowerZone.
For each byte the string: “1” means present “0” means not present
rack_location = <rsd_lib.resources.v2_1.common.rack_location.RackLocationField object>¶The ThermalZone physical location
status = <rsd_lib.base.StatusField object>¶The ThermalZone status
temperatures = <rsd_lib.resources.v2_1.chassis.thermal_zone.TemperatureSensorCollectionField object>¶Array of temperature sensors
volumetric_airflow = <sushy.resources.base.Field object>¶Rack Level PTAS Telemetry - Volumetric airflow in current ThermalZone
rsd_lib.resources.v2_1.chassis.thermal_zone.ThermalZoneCollection(connector, path, redfish_version=None, registries=None)¶